Manometer 1
Manometer 1

Manometer 1

MOQ : 1 Piece

Manometer 1 Specification

  • Pressure Range
  • 0 - 200 mm H2O
  • Connectivity Type
  • No Connectivity (Standalone)
  • Resolution
  • 1 mm
  • Flow Rate
  • Indirect measurement (Requires external setup)
  • Capacity
  • Single/dual scale measurement
  • Measurement Range
  • 0 - 200 mm H2O
  • Protection
  • No electrical protection; standard glass body
  • Sensor Type
  • Non-electronic (Liquid Column Meniscus)
  • Application Media
  • Air, Non-corrosive Gases
  • Humidity %
  • Up to 90% RH (non-condensing)
  • Wind Speed
  • Not Measurable
  • Temperature Range
  • 0C to 50C (liquid limit)
  • Diameter
  • Tube diameter approx. 10 mm
  • Equipment Type
  • U-Tube Manometer
  • Material
  • Transparent Acrylic/Glass body, Rubber Stopper
  • Power Supply
  • Not Applicable (Mechanical)
  • Accuracy
  • 0.5% of Full Scale
  • Display Type
  • Analog Scale (Liquid Column)
  • Range
  • 0 - 200 mm H2O
  • End Connection
  • Hose Nipple/Nozzle
  • Weight
  • Approx. 250 grams
  • Calibration
  • Factory calibrated, field calibration possible
  • Readout
  • Direct manual reading from graduated scale
  • Liquid Used
  • Usually Water or Manometer Fluid
  • Operating Principle
  • Differential Pressure via Liquid Displacement
  • Manometric Fluid Color
  • Dyed for enhanced visibility
  • Finish
  • Clear polished, scale marking in black
  • Tube Length
  • Approx. 250 mm (visible scale)
  • Mounting Type
  • Wall Mount or Stand Mount
 

Manometer 1 Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 10 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About Manometer 1



Hot deal alert! Explore the transcendent performance of the Manometer 1, meticulously engineered for outstanding precision in measuring differential pressure via liquid displacement. With factory calibration and sublime analog scale accuracy (0.5% FS), this U-Tube Manometer supports both wall and stand mounting. Its clear polished acrylic/glass body, vivid dyed fluid, and black scale markings ensure direct, effortless readings from a 250 mm tube. Procure this standalone marvel (no power required) for reliable measurements across air and non-corrosive gases. Perfect for labs and industry, it redefines practical innovation in India.

Versatile Usage & Diverse Applications

The Manometer 1 excels in monitoring differential pressure within HVAC systems, laboratory experiments, and industrial processes involving air and non-corrosive gases. Its flexibility allows it to be used as either a stationary wall-mount or portable stand-mount unit. Ideal for both educational and professional environments, it accommodates single or dual scale measurements, making it indispensable for quality assurance, research, and general pressure monitoring tasks across various sectors.


Supply Chain Excellence & Domestic Delivery

We ensure streamlined packing & dispatch for the Manometer 1, providing timely drop-off and secure shipment across India's primary markets. Valuation is transparent, with multiple payment terms available for your convenience. Our robust supply ability meets both bulk and singular orders, ensuring you receive outstanding products with each transaction. Trustworthy manufacturer, supplier, and trader networks guarantee that your procurement process remains smooth and reliable, from initial order to final delivery.


FAQ's of Manometer 1:


Q: How does the Manometer 1 measure differential pressure?

A: The Manometer 1 uses a non-electronic, liquid column meniscus system to display differential pressure between two points. The liquid displacement aligns with its analog graduated scale, providing direct manual readout.

Q: What liquids can be used in the Manometer 1 for measurements?

A: Typically, the Manometer 1 operates with water or specialized manometric fluids, which are dyed for enhanced visibility on the scale.

Q: Where can the Manometer 1 be mounted or installed?

A: The manometer is designed for flexibility; it can be wall-mounted for stationary use or stand-mounted for portable applications to suit different operational environments.

Q: When is field calibration required for the Manometer 1?

A: While the device is factory calibrated, field calibration is recommended periodically or after any fluid change, ensuring ongoing measurement accuracy during prolonged use.

Q: What are the primary applications for the Manometer 1?

A: Its primary use is in air and non-corrosive gas pressure measurement for HVAC systems, laboratories, and various industrial applications that demand accurate low-pressure monitoring.

Q: How does the packing and dispatch process work for this product?

A: Each unit undergoes careful evaluation, followed by secure packing to prevent damage during transit. Prompt dispatch and dependable drop-off services are ensured throughout main domestic markets in India.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Miscellaneous Category

Digital Flowmeter

Digital Flowmeter

Minimum Order Quantity : 1 Piece

Accuracy : 1% of F.S.

Connectivity Type : 420mA Output / RS485 Modbus

Protection : IP65

Material : Stainless Steel / ABS

Sensor Type : Turbine / Electromagnetic

OTI Transmitter

OTI Transmitter

Minimum Order Quantity : 1 Piece

Accuracy : 1% of FS

Connectivity Type : Electrical Terminal Connection

Protection : Weatherproof Enclosure

Material : Stainless Steel / Aluminum Housing

Sensor Type : Capillary Sensor / Bulb Sensor

Pressure Transmitter & Display

Pressure Transmitter & Display

Minimum Order Quantity : 1 Piece

Accuracy : 0.25% F.S.

Connectivity Type : 2wire/420 mA output

Protection : IP65

Material : Stainless Steel

Sensor Type : Piezoresistive

Wika Pressure Switch

Wika Pressure Switch

Minimum Order Quantity : 1 Piece

Accuracy : Set point repeatability 1 % of end scale

Connectivity Type : Electrical connection screw terminals

Protection : IP65

Material : Stainless Steel

Sensor Type : Mechanical (Piston or Diaphragm)



Back to top